unveiledsolectveganraspiContactLog inRegister
  • solect
  • vegan
  • raspi
  • Contact

  • Register

Electrics

  • Front Page
  • Latest comments
  • Log in
  1. Electrics
  2. Installation: Caravan
  3. Caravan Batteries
  4. 2020
  5. 05|May

05|May

Morning Low :: ≥ 12.63 | < 12.63 | < 12.39 | < 12.03     Yield :: ≥ 900 | ≥ 540 | ≥ 230 | ≥ 100 | ≤ 90

Morning Low is the voltage before any charge or use, if I'm up, else it is the lower value of max and min.

Yield is the power used including power via the inverter. ~  I  Indicates Inverter Use (Fridge + +)



31st May : ML V=12.67   Y=970Wh   I 
30th May : ML V=12.71⇖Y=990Wh   I 
29th May : ML V=12.71⇖Y=1.02KWh   I 
28th May : ML V=12.78⇖Y=940Wh   I 
27th May : ML V=12.74⇖Y=900Wh   I 
26th May : ML V=12.81⇖Y=870Wh   I 
25th May : ML V=12.70⇖Y=710Wh   I 
24th May : ML V=12.70⇖Y=600Wh   I 
23rd May : ML V=12.74⇖Y=550Wh   I 
22nd May: ML V=12.84⇖Y=60Wh Low yield as the battery is near capacity and little daytime load.
21st May : ML V=12.74⇖Y=760Wh   I 
20th May : ML V=12.74⇖Y=750Wh   I 
19th May : ML V=12.77⇖Y=330Wh   I 
18th May : ML V=12.71⇖Y=820Wh   I 
17th May : ML V=12.75⇖Y=770Wh   I 
16th May : ML V=12.76⇖Y=370Wh   I 
15th May : ML V=12.72⇖Y=860Wh   I 
14th May : ML V=12.78⇖Y=810Wh   I 
13th May : ML V=12.59⇖Y=620Wh   I  Install invoked equalisation at 15.94v with a max 4.8A for 4 hours
12th May The Rolls S12 27 specific gravity just before installation around sunset was:
1: 1.260 | 2: 1.265 | 3: 1.250 | 4: 1.250 | 5: 1.245 | 6: 1.250



Yield :: ≥ 610 | ≤ 600 | ≤ 450 | ≤ 320 | ≤ 190 | ≤ 90   P : Power Tools | F : Fridge


12th May : ML V=12.59⇖Y=960Wh  F
Have swapped battery from Gavin's 41Ah to the new Rolls S12 27 so will be setting a new MPPT profile. 22Kw have been yeilded to the 41Ah since ???

11th May : ML V=12.63⇖Y=790Wh  F
10th May : ML V=12.67⇖Y=440Wh  F
9th May ::: ML V=12.72⇖Y=700Wh  F

8th May ::: ML V=12.83⇖Y=390Wh Inverter downgraded from Victron 1200w > SkyTronic 300w so no more power tool usage.  F

7th May ::: ML V=12.59⇖Y=590Wh   ML 12.59 ?? The only reason I can think of is that the battery only went to float very late as I had the inverter on all day. This means that the ABS/FLT settings do not readily bring it to 100%  P  F   Also controller was reset later in the day as I disconnected to remove the inverter.

6th May ::: ML V=12.60⇖Y=770Wh   ML 12.60 ??  F
5th May ::: ML V=12.63⇖Y=200Wh
4th May ::: ML V=12.67⇖Y=540Wh  F
3rd May ::: ML V=12.67⇖Y=200Wh
2nd May :: ML V=12.74⇖Y=500Wh  F
1st May ::: ML V=12.63⇖Y=290Wh

Created by roger • Last edit by roger on 31/05/20 09:36 pm

No feedback yet

Leave a comment

In order to leave a comment Log in now! or Register now!

Comment feed for this post

Content Hierarchy

  • Batteries:~ Rechargable
  • Battery Charging
  • Battery Manufacturers
  • Battery Temperature
  • Cables and Wires
  • Charge Controllers
  • Fusing and Isolating
  • General Topics
  • Generators
  • Installation: Caravan
    • Caravan Batteries
      • 2018
      • 2019
      • 2020
        • 01|January
        • 02|February
        • 03|March
        • 04|April
        • 05|May
        • 06|June
        • 07|July
        • 08|August
        • 09|September
        • 10|October
        • 11|November
        • 12|December
        • Rolls S12 27
        • S12 27 Specific Gravity
      • 2021
      • 6 Nov 2014
      • Batteries 3 & 1
      • Batteries 4 & 2
      • Munufacturer: Surrette
      • Supplier Barden's
    • Electric Distribution in Caravan
    • Old Caravan Settings
  • Installation: Workshop
  • Inverters
  • Manufacturers
  • Miscellaneous
  • Photovoltaic Panels
  • Suppliers
  • Tools
  • Victron
June 2022
Mon Tue Wed Thu Fri Sat Sun
    1 2 3 4 5
6 7 8 9 10 11 12
13 14 15 16 17 18 19
20 21 22 23 24 25 26
27 28 29 30      
 << <   > >>
Blog software

This collection ©2022 by roger • Contact • Help • b2evolution CCMS