- Electrics
- Installation: Workshop
- Batteries
- S6 145 Specific Gravity
S6 145 Specific Gravity
I have labeled the two S6 145s A and B
and the cells in each are respectively (neg to pos), (pos to neg) ~ 1,2,3
and the cells in each are respectively (neg to pos), (pos to neg) ~ 1,2,3
Specific Gravity Readings
May 12th just before sunset.
A1 = 1.280 :: A2 = 1.275 :: A3 = 1.250 | B1 =1.280 :: B2 = 1.275 :: B3 = 1.260
This was before charging and I broke the hydrometer when cleaning so couldn't check the SG during or after charging which aslo included an automatic equalisation.
May 28th Mid afternoon when on float
A1 = 1.290 :: A2 = 1.292 :: A3 = 1.292 | B1 =1.292 :: B2 = 1.292 :: B3 = 1.260
The new Durite 472 has a thermometer for temp coefficients and although it was difficult to read it appears as though at least 6 points should be added, i.e. 1.290 becomes 1.296.
I spoke to Scotty at Durite who said SG's should be within 1%, i.e. 1.290 &plusmin; .0129 (0.013) so a range of 1.277 to 1.303 or 0.26 max diff.
Created by roger • Last edit by roger on 16/11/20 05:29 pm